当前位置:首页 > 技术文章 >鸟牌射频功率计探头选型表

鸟牌射频功率计探头选型表

点击次数:3526 更新时间:2014-02-07

鸟牌射频功率计探头选型表

ELEMENT SELECTION GUIDE

 

Wattmeter Model

Select Element from Table(s)

3128A

1, 2, 3, 3A, 4, 6, 14*

3170A

1, 2, 3, 3A, 4, 6, 14*

43

1, 2, 3, 3A, 4, 6, 14*

43P

1, 2, 3, 3A, 4, 5, 6

430

请看表①, 1 5/8AA

4314B

1, 2, 3, 3A, 4, 5, 6, 14*

4391A

1, 2, 3, 3A, 4, 5, 6, 14*

4410A, 4412A

请看表②

4431

1, 2, 3, 3A, 4, 6, 14*

4521, 4522

1, 2, 3, 3A, 4, 6, 14*

4526

1, 2, 3, 3A, 4, 6, 14*

4527

2 MHz to 512 MHz elements in 1,2, 6,14*

 

* Table 14 describes coupler elements used for RF sampling. The instrument meter does not read when these elements are installed, but simply serves as a line section.

 

 

ELEMENT TABLE FREQUENCY & POWER LIMITS

 

ELEMENT

ABLET

MIN. PWR

(WATTS F.S.)

MAX. PWR

(WATTS F.S.)

MIN. FREQ

(MHz)

MAX. FREQ

(MHz)

APM

1

1000

2

    2300

1

5

5000

2

1000

2

1

2.5

25

1000

3

1

250

950

2700

3A

0.1

0.5

950

2600

4

1000

10000

0.45

2.5

5

500

10000

2

1260

6

0.1

0.5

45

1000

8

50

25,000

0.45

2300

9

0.01

10

30

1000

9A

0.001

1

864

970

10

0.1

100

25

2300

11

1

1000

2

1000

12

10

10000

0.2

30

14

1000

1000

50

1250

 

 

 

 

TABLE 1 — STANDARD ELEMENT

 

 

  

Frequency Bands (MHz)

Power       Range

2-30

25-60

50-125

100-250

200-500

400-1000

5 W

5B

5C

5D

5E

10 W

10A

10B

10C

10D

10E

25 W

2

25B

25C

25D

25E

50 W

50H

50A

50B

50C

50D

50E

100 W

100H

100A

100B

100C

100D

100E

250 W

250H

250A

250B

250C

250D

250E

500 W

500H

500A

500B

500C

500D

500E

1000 W

1000H

1000A

1000B

1000C

1000D

1000E

2500 W

2500H

5000 W

5000H

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 2 — LOW-POWER ELEMENTS

 

1 Watt

 

Frequency (MHz)

40-

50

50-

60

60-

80

80-

90

95-

125

110-

160

150-

250

200-

300

275-

450

425-

850

800-

1000

Part Number

040-

1

050-

1

060-

1

080-

1

095-

1

110-

1

150-

1

200-

1

275-

1

425-

1

801-

1

 

 

 

2.5 Watt

 

Frequency (MHz)        

25-

30

30-

40

40-

50

50-

60

60-

80

80-

95

95-

150

150-

250

200-

300

250-

450

400-

850

800-

1000

Part Number

025-

2

030-

2

040-

2

050-

2

060-

2

080-

2

095-

2

150-

2

200-

2

250-

2

400-

2

801-

2

 

 

 

 

TABLE 3 — HIGH-FREQUENCY ELEMENTS, ENTIRE TABLE ±8% FS

 

 

  

Frequency Bands (MHz)

Power Range

950-

1260

1100-

1800

1700-

1990

1990-

2200

2200-

2300

2300-

2400

2400-

2500

2500-

2600

2600-

2700

1 W

1J

1K

1L1

1L2

1M

431-

17

431-

20

431-

23

431-

120

2.5 W

2.5J

2.5K

2.5L1

2.5L2

2.5M

431-

110

431-

107

431-

108

431-

117

5 W

5J

5K

5L1

5L2

5M

432-

15

432-

28

432-

2

432-

12

10 W

10J

10K

10L1

10L2

10M

432-

125

432-

141

432-

102

432-

104

25 W

25J

25K

25L1

25L2

25M

433-

19

433-

20

433-

35

433-

36

50 W

50J

50K

50L1

50L2

50M

433-

37

433-

38

433-

163

433-

164

100 W

100J

 

250 W

250J

 

 

 

 

 

TABLE 3A — HIGH FREQUENCY MILLIWATT ELEMENTS

 

 

  

Frequency Bands (MHz)

Power Range

950-

1260

1250-

1500

1500-

1700

1700-

2200

2300-

2400

2400-

2500

2500-

2600

100 mW

430-

82

430-

209

430-

210

430-

178

430-

211

430-

182

250 mW

430-

1

430-

239

430-

240

430-

241

500 mW

430-

259

430-

95

430-

159

 

 

 

 

TABLE 4 — LOW-FREQUENCY ELEMENTS

 

Frequency Band

 

Power Range

.45 - 2.5 MHz

1000 W

1000P

2500 W

2500P

5000 W

5000P

10000 W

10000P

 

 

 

 

TABLE 5 — PULSE-POWER ELEMENTS, ENTIRE TABLE  ±8% OF FULL SCALE

 

Frequency Bands (MHz)

 

Power Range

2-30

25-60

50-125

100-250

400-1000

950-1260

500 W

500J

1000 W

1000J

2500 W

2500A

2500B

2500C

2500E

2500J

5000 W

5000A

5000B

5000C

5000E

5000J

10000 W

10000H

10000B

10000E

 

Elements 500 - 1000 Watts, 950 - 1260 MHz, are rated at 100 Watts avg.

Elements 2500 Watts and higher, 25-1000 MHz, are rated at 1000 Watts avg.

Elements are capable of reading peak and average power.

 

 

TABLE 6 — MILLIWATT ELEMENTS

 

100 mW

Frequency (MHz)

45-

50

72-

76

108-

136

135-

175

320-

340

328-

336

400-

420

420-

450

450-

470

600-

800

800-

1000

Cat. No.

430-

266

430-

2

430-

57

430-

86

430-

205

430-

3

430-

7

430-

208

430-

8

430-

169

430-

263

 

 

 

250 mW

Frequency (MHz)

72-

76

88-

108

105-

120

116-

126

130-

150

190-

210

450-

470

800-

1000

Cat. No.

430-

22

430-

217

430-

20

430-

48

430-

13

430-

65

430-

61

430-

264

 

 

 

500 mW

Frequency (MHz)

72-

76

88-

108

105-

120

120-

136

136-

150

240-

290

290-

340

340-

360

350-

400

400-

450

450-

500

600-

800

800-

1000

Cat. No.

430-

33

430-

247

430-

26

430-

248

430-

249

430-

27

430-

253

430-

157

430-

254

430-

255

430-

256

430-

258

430-

265

 

 

 

 

NONDIRECTIONAL SAMPLER ELEMENTS FOR QC-TYPE OR 7/8" EIA LINE

 

Frequency Band (MHz)

Nominal Coupling

Max. Main Line Power

Model

25-1000

-50 dB ± 2 dB

(-66 dB @ 2 MHz)

500W

4274-025

100-400

-35 to -48 dB (±1 dB) Adjustable

500W

4274-050

 

 

 

 

TABLE 14 — DIRECTIONAL COUPLER ELEMENTS

FOR QC-TYPE OR 7/8" EIA LINE

 

Frequency

Band (MHz)

Nominal

Coupling

Max. Main

Line Power

Model

50-100

-40 dB

1 kW

400-50

75-150

-40 dB

1 kW

400-75

125-250

-40 dB

1 kW

400-125

225-450

-40 dB

1 kW

400-225

400-800

-40 dB

1 kW

400-400

750-1250

-40 dB

1 kW

400-750

 

 

 

 

TABLE 1 5/8AA — STANDARD ELEMENTS 30 uA

 

 

Frequency Bands (MHz)

Power Range

2-30

50-125

100-250

400-1000

100 W

100B12

100C12

100E12

250 W

250B12

250C12

250E12

500 W

500H12

500B12

500C12

500E12

1000 W

1000H12

1000B12

1000C12

1000E12

2500 W

2500H12

2500B12

2500C12

2500E12

5000 W

5000H12

5000B12

5000C12

5000E12

10 kW

10KH12

10KB12

25 kW

25KH12

25KB12

 

 

 

 

表① 430 Elements

 

 

Frequency (MHz)

Power

.45-2.5

2–30

50-125

100-250

400-1000

1100-1800

50 W

50K7

2500 W

2500B7

2500C7

2500E7

5000 W

5000B7

10 kW

10KH7

25 kW

25KP7

 

 

 

 

表② 4410 Elements

Table 9 - Full-Scale Power and Frequency Ranges 0-10, 30, 100, 300 Milliwatts, 1, 3, 10 Watts

 

MHz

30-

50

50-

88

88-

108

-

150-

250

225-

400

400-

800

800-

900

900-

1000

Model

4410-

20

4410-

21

4410-

27

-

4410-

23

4410-

24

4410-

25

4410-

26

4410-

28

 

Table 10 - Full-Scale Power and Frequency Ranges 0-100, 300 Milliwatts, 1, 3, 10, 30, 100 Watts

 

MHz

25-

80

50-

125

100-

250

200-

500

400-

1000

1000-

1800

1800-

2300

Model

4410-

10

4410-

11

4410-

12

4410-

13

4410-

14

4410-

15*

4410-

16*

 

Table 11 - Full-Scale Power and Frequency Ranges 0-1, 3, 10, 30, 100, 300, 1000 Watts

 

MHz

2–30

25-80

50-200

144-520

200-1000

Model

4410-3

4410-5

4410-6

4410-7

4410-8

 

Table 12 - Full-Scale Power and Frequency Ranges 0-10, 30, 100, 300, 1000, 3000, 10,000 Watts

 

MHz

0.2-0.535

0.45-2.5

2-30

Model

4410-1

4410-2

4410-4

 

手机: